Description
the ARM0156 minimizes axial play and extends the operational life of the condenser assembly
Technicians should verify the actual dimensions against the existing filter track before attempting installation in non-Lennox equipment
As a direct factory replacement for legacy part numbers 239-43676-02 and 239-43676-02C
Direct Retrofit Compatibility: Serves as the precise replacement for the Barber Colman K-335
Nordyne 622337 Transformer the ARM0156 minimizes axial playWhen you are in the field and dealing with a dropped control circuit on a Nordyne, Intertherm, or Miller furnace, a failed Nordyne 622337 transformer is a common culprit. This genuine OEM HVAC transformer is a critical step down component designed to convert 120V primary line voltage to a stabilized 24V secondary output, providing the necessary 40VA power for 24 volt control boards, contactors, and thermostats. Built with a rugged black metal core and